The Covidien Valleylab FX8 represents a source of energy that is managed by an electrosurgical unit. This energy platform, known as the Valleylab FX8, utilizes TissueTect, an innovative technology that detects and adapts to different types of tissue. The FX8 serves as the predecessor to the Medtronic Valleylab FT10 Energy Platform. Within the Valleylab energy source, users have access to various modes including cutting, coagulation, and soft coagulation. Moreover, this energy source facilitates shared coagulation, enabling two surgeons to operate simultaneously on a single patient.

FEATURES:

  • Valleylab mode provides a unique combination of monopolar hemostasis and division
  • TissueFect technology to ensure the precise energy is delivered for the correct type of tissue
  • Shared coag mode allows for two surgeons to work at once on a patient
  • Precise delivery of monopolar and bipolar energy
  • Power control during monopolar energy delivery that’s five times better than the
  • Force Triad Energy Platform
  • Tissue monitoring that’s 2600 times faster than the Force FX Electrosurgical Generator

    SPECIFICATIONS:

    • Manufacturer: Covidien/Valleylab
    • Part Number: (OEM): VALLEYLAB FX8
    • Category: Electrosurgical Units
    • Condition: Refurbished
    • Weight: 19.5lbs.
    • Warranty: 3 Months

    • Dimensions:
      • Height: 14.6 cm (5.73 in)
      • Width: 33.5 cm (13.18in)
      • Length: 43.6cm (17.15in)
      • Weight: 8.8kg (19.5lb)

    • General:
      • Output configuration: Isolated output
      • Cooling: Natural convection and fan
      • Display: 15.7 cm (6.2 in) LCD touchscreen
      • Enclosure: Magnesium
      • Mounting
        • Valleylab™ universal generator cart (VLFTCRT)
        • Operating room boom systems
        • Any stable, flat surface such as a table or cart top

    • Operating Parameters:
      • Ambient temperature range: 10°C to 40°C (50°F to 104°F)
      • Relative humidity: 15% to 85% non-condensing
      • Atmospheric pressure: 700 to 1060 millibars

    • Temperature & Storage:
      • Ambient temperature range: -10°C to 60°C (14°F to 140°F)
      • Relative humidity: 15% to 90% non-condensing
      • Atmospheric pressure: 500 to 1060 millibars

    • Input Power 100-127 VACe:
      • Line Ranges
        • Line Voltage Full Regulation Range: 90–140 VAC
        • Line Frequency: 47–63 Hz
      • Max VA Nominal Line Voltage: 660 VA
      • Max Mains Current: 6.6 ARMS
      • Max Heat Dissipation 180 W
      • Fuses
        • 10 A
        • Fuses (2) – 5 mm x 20 mm
        • 10 A, 250 V fast blow

    • Input Power 220-240 VAC:
      • Line Ranges
        • Line Voltage Full Regulation Range: 198-264 VAC
        • Line Frequency: 47–63 Hz
      • Max VA Nominal Line Voltage: 660 VA
      • Max Mains Current: 3.0 ARMS
      • Max Heat Dissipation 180 W
      • Fuses
        • 6.3 A
        • Fuses (2) – 5 mm x 20 mm
        • 6.3 A, 250 V fast blow

                      In addition please acknowledge the following disclaimer:

                      * IMPORTANT - PLEASE READ BEFORE PURCHASING! * All pictures of items being sold are used for reference purposes and are described as accurately as possible. If there is an error in a listing, we will try and resolve any issues to the best of our abilities that may arise before or after a sale. Complete units all come with a power cord and DO NOT come with any cables, sensors, manuals, accessories etc. unless otherwise noted in the description.

                      Purchaser agrees that seller is not liable for any injuries or damages of any kind associated in any way with this equipment. Purchaser agrees to indemnify and hold harmless seller and seller's officers, directors, employees, agents, and shareholders against any and all claims, liabilities, obligations, demands, cost and expenses of every kind and nature, including but not limited to attorney's fees and litigation expenses, from or related to the equipment and any use thereof.

                      * NOTE - FDA Regulation and Certification: "The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item."

                      This unit or item will ship anywhere in the continental United States via FedEx Ground - Calculated. Please read our Shipping and Return policies for more details.