The Covidien/Valleylab Force 1C Electrosurgical Generator boasts a sleek and efficient design that perfectly caters to the needs of outpatient and office-based surgeries. Moreover, it meets the performance standards required for a wide array of inpatient general surgery procedures.

FEATURES:

  • Outpatient procedures to full range surgical applications
  • Monopolar and Bipolar outputs
  • Audible and visual alarms

    SPECIFICATIONS:

    • Manufacturer: Covidien/Valleylab
    • Part Number: (OEM): VALLEYLAB FORCE 1C
    • Category: Electrosurgical Units
    • Condition: Refurbished
    • Weight: 5.0lbs.
    • Warranty: 3 Months

    • Dimensions:
      • Dimensions: 6 × 11 × 17 inches (15 × 28 × 43 cm)
      • Weight: 5lbs (6.8 kg)

    • Output Waveform:
      • Cut: 516 kHz sinusoid
      • Blend 1: 516 kHz of the sinusoid at 70% duty cycle recurring at 31 kHz
      • Blend 2: 516 kHz bursts of the sinusoid at 45% duty cycle recurring at 31 kHz
      • Blend 3: 516 kHz bursts of the sinusoid at 20% duty cycle recurring at 31 kHz
      • Coag: 516 kHz damped sinusoidal bursts with a repetition frequency of 31 kHz
      • Micropolar: 516 kHz sinusoid, unmodulated

    • Output Characteristic:
      • Cut: 2400 Max. (open circuit) P-P voltage; 300 Rated Load ohms; 200 Nominal Power at rated load watts; 1.8 @ 100 W Crest Factor at rated load typical
      • Blend 1: 2800 Max. (open circuit) P-P voltage; 300 Rated Load ohms; 175 Nominal Power at rated load watts; 2.7 @ 100 W Crest Factor at rated load typical
      • Blend 2: 3200 Max. (open circuit) P-P voltage; 300 Rated Load ohms; 150 Nominal Power at rated load watts; 3.3 @ 100 W Crest Factor at rated load typical
      • Blend 3: 3600 Max. (open circuit) P-P voltage; 300 Rated Load ohms; 125 Nominal Power at rated load watts; 4.6 @ 100 W Crest Factor at rated load typical
      • Coag: 5200 Max. (open circuit) P-P voltage; 300 Rated Load ohms; 75 Nominal Power at rated load watts; 8.0 @ 50 W Crest Factor at rated load typical
      • Micropolar: 900 Max. (open circuit) P-P voltage; 100 Rated Load ohms; 50 Nominal Power at rated load watts; 1.8 @ 40 W Crest Factor at rated load typical

    • Power:
      • (Max. operating range: 85-135 or 170-270 VAC; Nominal operating range: 110-120 or 220-240 VAC)
      • Idle: 0.5 A Max. Current; 60 W Max. Power
      • Cut: 5.0 A Max. Current; 600 W Max. Power
      • Coag: 3.0 A Max. Current; 400 W Max. Power
      • Micropolar: 2.0 A Max. Current; 180 W Max. Power

    • Line Regulation:
      • Between 85-135 volts or 170-270 volts input, output power into nominal load will vary no more than 20% or 5 watts, whichever is greater

    • REM Contact Quality Mon:
      • Measurement frequency: 140 kHz ± 20 kHz. Measurement current: 3.0mA, maximum

    • Low Frequency Leakage:
      • Source current nominal polarity, intact chassis ground: <10 µA, ground open: <50 µA. Source current reverse polarity, ground open: <50 µA. sink current, 135 VAC applied, all inputs: <20 µ A. Chassis source current, ground open: <100 µA

    • Low Frequency Leakage:
      • Source current nominal polarity, intact chassis ground: <10 µA, ground open: <50 µA. Source current reverse polarity, ground open: <50 µA. sink current, 135 VAC applied, all inputs: <20 µ A. Chassis source current, ground open: <100 µA
      • Micropolar RF leakage current: <150 mA. Monopolar RF leakage current: <150 mA

                          In addition please acknowledge the following disclaimer:

                          * IMPORTANT - PLEASE READ BEFORE PURCHASING! * All pictures of items being sold are used for reference purposes and are described as accurately as possible. If there is an error in a listing, we will try and resolve any issues to the best of our abilities that may arise before or after a sale. Complete units all come with a power cord and DO NOT come with any cables, sensors, manuals, accessories etc. unless otherwise noted in the description.

                          Purchaser agrees that seller is not liable for any injuries or damages of any kind associated in any way with this equipment. Purchaser agrees to indemnify and hold harmless seller and seller's officers, directors, employees, agents, and shareholders against any and all claims, liabilities, obligations, demands, cost and expenses of every kind and nature, including but not limited to attorney's fees and litigation expenses, from or related to the equipment and any use thereof.

                          * NOTE - FDA Regulation and Certification: "The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item."