The Optima XR220amx is a self-contained, battery-operated mobile digital X-ray imaging system specifically engineered to conduct radiographic examinations at the point of care, eliminating the need to transport patients to the radiographic room when it is impractical or unsafe to do so.
This versatile system is well-suited for a wide range of routine radiographic procedures within a hospital setting, including but not limited to radiology departments, intensive care units, cardiac care units, emergency departments, operating rooms, orthopedic and pediatric units, as well as hospital rooms and clinics.
FEATURES:
- Battery operated
- Dual-motor drive
- Self-stopping bumper
- Dose area product meter
- Hand switch
- Extendable telescopic arm for tube placement
- Display, technique, and image acquisition tools in single integrated user interface
- Lightweight digital detector enclosure, designed for mobile use
- Attachable tether and detector holder for digital detector
- Allows technicians to make and process exposures while unit is charging
- Stand-by mode eliminates boot up cycles, allows exposures within 25 seconds
- Tablet holder
- Remote switch
- Barcode scanner
SPECIFICATIONS:
- Manufacturer: GE
- Part Number (OEM): OPTIMA XR220
- Category: Imaging
- Accessories: None
- Functional Condition: New/Refurbished
- Cosmetic Condition: Good
- Warranty: 30 Days
- Wireless Digital Detector:
- Detector battery can take up to 50 exposures per hour and provide enough power for 3 hours of use on a single charge
- Single panel (non-tiled) amorphous silicon detector with a Cesium Iodide scintillator
- Image area: 40.4 cm x 40.4 cm (15.9 in x15.9 in)
- Active matrix: 2024 x 2024 pixels
- Pixel Pitch: 200 microns
- Typical upper dynamic range: 7.8mR
- Typical DQE: @ 0lp/mm: 68%)
- Two handgrips
- Detector Environmental Conditions:
- Temperature:
- Operating: 15°C to 35°C
- Non-Operating: -0°C to 50°C (maximum change 20°C per hour)
- Humidity:
- Operating: 10% to 80% RH, noncondensing(max. change 30% per hour)
- Non-Operating: 10% to 95% RH, noncondensing (max. change 30% per hour)
- Power:
- Capable of 100-240 V nominal, 50/60 Hz operation
- System battery status display
- X-Ray Source:
- Nominal Tube Voltage (Radiographic) 40 ~ 150 kV
- Nominal Focal Spot size (IEC 60336):
- Large Focus: 1.2 mm
- Small Focus: 0.6 mm
- Anode Rotation Speed (minimal): 3200 min-1
- Permanent Filtration: 0.9 mm Al/75 kV IEC60522: 1999
- Maximum X-ray Tube Current
- Large Focus: 500 mA
- Small Focus: 200 mA
- Maximum Continuous Heat Dissipation: Without Air-circulator: 170 W (238 HU/s)
- Maximum anode heat units: 140 kHU
- Exposure time: 4.0 msec – 6.0 sec
In addition, please acknowledge the following disclaimer:
* IMPORTANT - PLEASE READ BEFORE PURCHASING! * All pictures of items being sold are used for reference purposes and are described as accurately as possible. If there is an error in a listing, we will try and resolve any issues to the best of our abilities that may arise before or after a sale. Complete units all come with a power cord and DO NOT come with any cables, sensors, manuals, accessories etc. unless otherwise noted in the description.
Purchaser agrees that seller is not liable for any injuries or damages of any kind associated in any way with this equipment. Purchaser agrees to indemnify and hold harmless seller and seller's officers, directors, employees, agents, and shareholders against any and all claims, liabilities, obligations, demands, cost and expenses of every kind and nature, including but not limited to attorney's fees and litigation expenses, from or related to the equipment and any use thereof.
* NOTE - FDA Regulation and Certification: "The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item."